• Telescopic butterfly valve
  • Telescopic butterfly valve
  • Telescopic butterfly valve
Telescopic butterfly valve
Telescopic butterfly valve
Telescopic butterfly valve
+

Share:

Telescopic butterfly valve

Telescopic butterfly valve for the flanged butterfly valve and pipe telescopic two functions as a whole, that can play a throttling role, but also to solve the temperature difference generated by the elimination of internal forces, that is, play a telescopic role. The valve can be used in electric power, metallurgy, petroleum, chemical industry, gas, urban heating, water and electricity papermaking, textile, medicine, food, water supply and drainage, energy, all non-corrosive gases, liquids, semi-fluids and solid powder pipelines and containers.

Contact Information

If you are interested in our products, Please contact us

Product Details

Telescopic butterfly valve

Telescopic butterfly valve for the flanged butterfly valve and pipe telescopic two functions as a whole, that can play a throttling role, but also to solve the temperature difference generated by the elimination of internal forces, that is, play a telescopic role. The valve can be used in electric power, metallurgy, petroleum, chemical industry, gas, urban heating, water and electricity papermaking, textile, medicine, food, water supply and drainage, energy, all non-corrosive gases, liquids, semi-fluids and solid powder pipelines and containers. Can be arbitrarily change the position of the installation, not affected by the medium, the flow direction, the other for the valve installation of the two flange spacing adjustment.


Telescopic butterfly valve installation instructions

1. The telescopic butterfly valve must be laid flat before installation, and do not bump at will.
2. The structure length of the telescopic butterfly valve is the minimum when it leaves the factory, and when it is installed, it is pulled to the installation length (that is, the design length). 3. When the length of the pipeline exceeds the length of the telescopic valve, please adjust the pipeline interval and do not force the telescopic valve to avoid damage to the telescopic valve.
4. The telescopic butterfly valve can be installed at any position for temperature compensation. After the pipeline installation is completed, supports shall be added at both ends along the axial direction of the pipeline to prevent the telescopic valve telescopic pipe from being pulled out (see Figure 1). The ground support force of the support shall be calculated according to the formula in the right column. It is strictly prohibited to remove the support during operation.
5. When the telescopic butterfly valve does not make temperature compensation, it is only installed and replaced. When it is convenient to repair the valve, it can be limited by bolts and clamped symmetrically.®In order to prevent the telescopic pipe pull out (see Figure 2), damage to the telescopic butterfly valve and pipeline device or building. The bolt diameter can be calculated according to the flange bolt diameter, bolt strength, test pressure and pipeline tension according to the above formula. It is strictly prohibited to remove the bolts during operation (bolts are provided separately).
6. Disassembly of collapsible butterfly valve is strictly prohibited at the pipeline construction site.
7. This telescopic butterfly valve has fine processing and tight coordination. Please do not stretch and press the short telescopic valve repeatedly on site. When the pipeline is installed, it is required that the pipeline at both ends of the telescopic butterfly knot must be concentric, and the two flange surfaces on the pipeline must be parallel.
8. Flange fixing bolts should be fastened symmetrically, and do not tighten flange fixing bolts unilaterally.
9. The telescopic pipe is installed behind the valve.
10. The telescopic part of the telescopic valve shall not be installed at the corner of the pipeline or at the end of the pipeline.
Features of telescopic butterfly valve

1. Novel design and unique structure
2. Small size and light weight
3. The operation is light and labor-saving, and the opening and closing are rapid
4. The sealing part can be adjusted and replaced, the sealing performance is reliable, the flow resistance is small, and the energy saving

Nominal diameter DN Nominal diameter Overall dimensions (reference value> External dimension(consult Connection size Conjunction Size
H H1 Lmax Most design extent Lmin Least design extent Design length L Design extent A B 0.6MPa 1.0MPa 1.6MPa
mm inch D D1 D2 n-d D D1 D2 n-d D D1 D2 n-d
50 2 80 309 164 138 151 180 200 140 110 88 4-14 165 125 99 4-18 165 125 99 4-18
65 2 ½ 95 337 190 154 172 180 200 160 130 108 4-14 185 145 118 4-18 185 145 118 4-18
80 3 98 347 195 163 177 180 200 190 150 124 4-18 200 160 132 8-18 200 160 132 8-18
100 4 114 373 227 184 206 180 200 210 170 144 4-18 220 180 156 8-18 220 180 156 8-18
125 5 128 405 254 201 215 180 200 240 200 174 8-18 250 210 184 8-18 250 210 184 8-18
150 6 139 440 240 195 225 270 280 265 225 199 8-18 285 240 211 8-22 285 240 211 8-22
200 8 174 612 265 215 245 400 425 320 280 254 8-18 340 295 266 8-22 340 295 266 12-22
250 10 215 693 295 235 265 400 425 375 335 309 12-18 395 350 319 12-22 405 355 319 12-26
300 12 245 747 308 254 282 450 560 440 395 363 12-22 445 400 370 12-22 460 410 370 12-26
350 14 270 802 325 271 300 450 560 490 445 413 12-22 505 460 429 16-22 520 470 429 16-26
400 16 305 991 345 283 314 535 580 540 495 463 16-22 565 515 480 16-26 580 525 480 16-30
450 18 325 1037 370 314 340 535 580 595 550 518 16-22 615 565 530 20-26 640 585 548 20-30
500 20 360 1127 377 316 346 535 580 645 600 568 20-22 670 620 582 20-26 715 650 609 20-33
600 24 445 1377 446 388 417 570 660 755 705 667 20-26 780 725 682 20-30 840 770 720 20-36
700 28 505 1496 445 395 425 750 550 860 810 772 24-26 895 840 794 24-30 910 840 794 24-36
800 32 560 1584 479 425 455 750 550 975 920 878 24-30 1015 950 901 24-33 1025 950 901 24-39
900 36 630 1676 515 455 485 750 550 1075 1020 978 24-30 1115 1050 1001 28-33 1125 1050 1001 28-39
1000 40 680 1760 525 465 495 900 750 1175 1120 1078 28-30 1230 1160 1112 28-36 1255 1170 1112 28-42
1200 48 795 2018 574 512 542 1000 925 1405 1340 1295 32-33 1455 1380 1328 32-39 1485 1390 1328 32-48
SBWF3(H/X)* SD343(H/X)-(6/10/16) Series Connection Size/Series connection dimensions

Get Quote

Note: Please leave your E-mail and our professionals will contact you as soon as possible!

Submit immediately

Related Products


National sales hotline 7*24 hours

Address: 801-805 Jingshan Road, Guannan Industrial Zone, jimei district, Xiamen City

Leave Us A Message

Thank you for your trust in us! Please leave your usual landline/mobile/E-mail number, and we will have a special customer service staff to confirm and arrange your message.

Submit
%{tishi_zhanwei}%
Business License